DISTRIBUTOR-FIRST SUPPLY PARTNER · SINCE 1999 RESOURCES · COMPRESSED AIR 101
SPC Company

Lesson 5: Leaks and Pressure Drop

These two problems cause more “we need a bigger compressor” calls than anything else. Most of the time the compressor is fine. The air is getting lost or choked on the way to the tool.

Leaks

Every system leaks. The question is how much. The DOE sourcebook says a poorly maintained plant typically leaks about 20 percent of its compressor output, and as high as 20 to 30 percent. A good leak program can bring that under 10 percent.

Small holes add up fast. From the published leak table at 100 psig, ideal-orifice figures:

Hole sizeAir lost (ideal orifice)
1/16 inabout 6.5 cfm
1/8 inabout 26 cfm
1/4 inabout 104 cfm

A real sharp-edged hole leaks about 60 percent of that, so a 1/4 in hole loses about 63 cfm. That is still the output of a 13 to 16 hp compressor (using the 4 to 5 cfm per hp rule of thumb from Lesson 2).

Where leaks hide: quick couplers, hose ends, thread joints, FRL drains stuck open, worn cylinder rod seals, valves, and condensate drains that blow air.

Quick leak estimate. This works on a load/unload compressor only. Shut down production so nothing is using air. Time how long the compressor runs loaded (T) and how long it runs unloaded (t) over several cycles. The Compressed Air Challenge formula:

Leakage % = (T x 100) / (T + t)

If it runs loaded 20 seconds and unloads 40 seconds with no production, leaks are about 33 percent of capacity.

An ultrasonic leak detector finds leaks you cannot hear on a running floor.

Pressure drop

Pressure drop is the pressure lost between the compressor and the tool. Every pipe, hose, fitting, filter, and coupler costs some.

The DOE sourcebook says a properly designed system loses much less than 10 percent of compressor discharge pressure from the receiver outlet to the point of use. At 100 psig, that is well under 10 psi.

Common causes:

  • Pipe or hose too small for the flow
  • Dirty filter elements, especially point-of-use filters nobody changes
  • Restrictive quick couplers
  • Long hose runs and too many fittings
  • Undersized FRLs and regulators that droop under flow

Why it costs money: when tools starve, the usual reaction is to turn up the compressor. Rule of thumb from the sourcebook: in systems around 100 psig, every 2 psi of extra pressure adds about 1 percent to energy use. Higher pressure also pushes more air out of every leak.

Shop example

A customer turned their compressor from 100 to 120 psig because tools at the far end are weak. Before you quote a bigger machine, ask them to read pressure at the receiver and at the tool while it runs. If the tool sees 75 psig with the receiver at 120, the problem is the path, not the compressor.


Sources

  1. DOE/Compressed Air Challenge, Improving Compressed Air System Performance, 3rd ed. (pressure drop much less than 10 percent from receiver outlet to point of use; 2 psi per 1 percent rule of thumb).
  2. Compressed Air Challenge, Fact Sheet 7, Compressed Air System Leaks (leaks typically about 20 percent, as high as 20 to 30 percent, under 10 percent with a program; leakage percent formula for load/unload compressors).
  3. Compressed Air Challenge / ENERGY STAR leak table at 100 psig (6.5, 26, 104 cfm). Table values assume an ideal orifice (discharge coefficient 1.0); its footnote gives 0.97 for a well-rounded orifice and 0.61 for a sharp-edged orifice. 104 x 0.61 = about 63 cfm.
  4. The 4 to 5 cfm per hp comparison is an industry rule of thumb, not a rating. 63 / 5 = about 13 hp; 63 / 4 = about 16 hp.
/ Quiz

Check your understanding

5 questions · shows why after each

1.Per the DOE leak table, about how much air does a 1/4 in hole lose at 100 psig?

2.With no production running, a load/unload compressor runs loaded 20 seconds and unloads 40 seconds. Estimated leakage?

3.Per the DOE sourcebook, a properly designed system loses much less than what share of discharge pressure from receiver outlet to point of use?

4.Which is a common cause of pressure drop at the tool?

5.Why is turning up the compressor a poor fix for weak tools?

Your score
0 of 5

Answer all 5 to see how you did.

Got a customer question this lesson did not cover?

Send it to us with what you know. We will help you answer it and quote it.

Request a Quote